This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 465.48(9)(c)3.c. c. Before using the sensor for the first time or when relocating or replacing the sensor, perform a validation check by comparing the sensor output to a calibrated temperature measurement device or by comparing the sensor output to a simulated temperature.
NR 465.48(9)(c)3.d. d. Conduct an accuracy audit every quarter and after every deviation. Accuracy audit methods include comparisons of sensor output to redundant temperature sensors, to calibrated temperature measurement devices, or to temperature simulation devices.
NR 465.48(9)(c)3.e. e. Conduct a visual inspection of each sensor every quarter if redundant temperature sensors are not used.
NR 465.48(9)(d) (d) Regenerative carbon adsorbers. If you are using a regenerative carbon adsorber as an add-on control device, you shall monitor the total regeneration desorbing gas mass flow for each regeneration cycle, the carbon bed temperature after each regeneration and cooling cycle, and comply with par. (a) 3. to 5. and subds. 1. to 3.
NR 465.48(9)(d)1. 1. The regeneration desorbing gas mass flow monitor shall be an integrating device having a measurement sensitivity of plus or minus 10% capable of recording the total regeneration desorbing gas mass flow for each regeneration cycle.
NR 465.48(9)(d)2. 2. The carbon bed temperature monitor shall be capable of recording the temperature within 15 minutes of completing any carbon bed cooling cycle.
NR 465.48(9)(d)3. 3. For all regenerative carbon adsorbers, you shall meet the requirements in par. (c) 3. a. to e. for each temperature monitoring device.
NR 465.48(9)(e) (e) Condensers. If you are using a condenser, you shall monitor the condenser outlet, or product side, gas temperature and comply with par. (a) and subds. 1. and 2.
NR 465.48(9)(e)1. 1. The temperature monitor shall provide a gas temperature record at least once every 15 minutes.
NR 465.48(9)(e)2. 2. For all condensers, you shall meet the requirements in par. (c) 3. a. to e. for each temperature monitoring device.
NR 465.48(9)(f) (f) Concentrators. If you are using a concentrator, such as a zeolite wheel or rotary carbon bed concentrator, you shall comply with the requirements in subds. 1. and 2.
NR 465.48(9)(f)1. 1. You shall install a temperature monitor in the desorption gas stream. The temperature monitor shall meet the requirements in pars. (a) and (c) 3.
NR 465.48(9)(f)2. 2. You shall install a device to monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure monitoring device shall meet the requirements in pars. (a) and (g) 2.
NR 465.48(9)(g) (g) Emission capture systems. The capture system monitoring system shall comply with the applicable requirements in subds. 1. and 2. If the source is a magnet wire coating machine, you may use the procedures in section 2.0 of 40 CFR part 63, Subpart MMMM, Appendix A, incorporated by reference in s. NR 484.04 (24g), as an alternative.
NR 465.48(9)(g)1. 1. For each flow measurement device, you shall meet the requirements in par. (a) and the requirements in subd. 1. a. to g.
NR 465.48(9)(g)1.a. a. Locate a flow sensor in a position that provides a representative flow measurement in the duct from each capture device in the emission capture system to the add-on control device.
NR 465.48(9)(g)1.b. b. Use a flow sensor with an accuracy of at least 10% of the flow.
NR 465.48(9)(g)1.c. c. Perform an initial sensor calibration in accordance with the manufacturer's requirements.
NR 465.48(9)(g)1.d. d. Perform a validation check before initial use or upon relocation or replacement of a sensor. Validation checks include comparison of sensor values with electronic signal simulations or via relative accuracy testing.
NR 465.48(9)(g)1.e. e. Conduct an accuracy audit every quarter and after every deviation. Accuracy audit methods include comparisons of sensor values with electronic signal simulations or via relative accuracy testing.
NR 465.48(9)(g)1.f. f. Perform leak checks monthly.
NR 465.48(9)(g)1.g. g. Perform visual inspections of the sensor system quarterly if there is no redundant sensor.
NR 465.48(9)(g)2. 2. For each pressure drop measurement device, you shall comply with the requirements in par. (a) and the requirements in subd. 2. a. to g.
NR 465.48(9)(g)2.a. a. Locate the pressure sensor in or as close to a position that provides a representative measurement of the pressure drop across each opening you are monitoring.
NR 465.48(9)(g)2.b. b. Use a pressure sensor with an accuracy of at least 0.5 inches of water column or 5% of the measured value, whichever is larger.
NR 465.48(9)(g)2.c. c. Perform an initial calibration of the sensor according to the manufacturer's requirements.
NR 465.48(9)(g)2.d. d. Conduct a validation check before initial operation or upon relocation or replacement of a sensor. Validation checks include comparison of sensor values to calibrated pressure measurement devices or to pressure simulation using calibrated pressure sources.
NR 465.48(9)(g)2.e. e. Conduct accuracy audits every quarter and after every deviation. Accuracy audits include comparison of sensor values to calibrated pressure measurement devices or to pressure simulation using calibrated pressure sources.
NR 465.48(9)(g)2.f. f. Perform monthly leak checks on pressure connections. A pressure of at least 1.0 inches of water column to the connection shall yield a stable sensor result for at least 15 seconds.
NR 465.48(9)(g)2.g. g. Perform a visual inspection of the sensor at least monthly if there is no redundant sensor.
Table 1
Operating Limits if Using the Emission Rate With Add-On Controls Option in s. NR 465.43 (2) (c)
If you are required to comply with operating limits by s. NR 465.43 (3) (b), you shall comply with the applicable operating limits in the following table. - See PDF for table PDF - See PDF for table PDF
Table 2
Default Organic HAP Mass Fraction for Solvents and Solvent Blends
You may use the mass fraction values in the following table for solvent blends for which you do not have test data or manufacturer's formulation data and which match either the solvent blend name or the chemical abstract series (CAS) number. If a solvent blend matches both the name and CAS number for an entry, that entry's organic HAP mass fraction shall be used for that solvent blend. Otherwise, use the organic HAP mass fraction for the entry matching either the solvent blend name or CAS number, or use the organic HAP mass fraction from Table 3 of this subchapter if neither the name or CAS number match. - See PDF for table PDF
Table 3
Default Organic HAP Mass Fraction for Petroleum Solvent Groups a
You may use the mass fraction values in the following table for solvent blends for which you do not have test data or manufacturer's formulation data. - See PDF for table PDF
NR 465.48 History History: CR 05-040: cr. Register February 2006 No. 602, eff. 3-1-06.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.